SECURITY ELEMENTS

SECURITY ELEMENTS

SERVICES:

  • Distribution of equipment and accessories to prevent fires and explosions in industrial plants, thus protecting the health and life of workers, and reducing the risk of irreparable damage and possible losses in production.
  • Installation or change due to breakage or deterioration of the existing ones in equipment owned by the client.

ELEMENT OF PROTECTION IN EQUIPMENT WITH ATEX EXPLOSION RISK:

  • The commissioning of ATEX equipment must be carried out by qualified personnel
  • Fits Standard 94/9 / CE Atex
  • The control of the essential requirements of safety and health is guaranteed by the following regulations:
  • Certificate with directive EU34 / 2014.
  • Standard: UNE EN14797:2006, UNE EN 14491:2012, UNE EN 13463-1:2009, UNE EN 1127-1:2011, UNE EN 14994:2007, UNE EN 13980:2004, CE 0477 EUM1  11 Atex 0592 II GD

VENT PANELS:

Effective protection for deposits and technological equipment against ruptures and destruction during a possible explosion.

The storage and handling of industrial dusts are usually related to the potential danger of an explosion. These panels for explosive discharge are a perfect solution to reduce this risk and eliminate the losses that follow those explosions.

Vent panels offer a very effective and economical solution to protect against the damage caused by an explosion of solids.

Among its main advantages are:

  • High effectiveness and confidence
  • Long life of service
  • Resistivity against abrasion and impacts of mechanical particles and environmental conditions
  • Easy installation, change and easy availability of spare parts
  • Panels and auxiliary equipment of variable sizes
  • Economically advantageous solution

FLAME ARRESTERS:

A flame arrestor will eliminate a flame that will pass through it.

In the case of conductions with a certain length, the flame can acquire the character of a Detonation, therefore the Flame arrester must be designed to withstand the overpressure that this episode will entail.

  • Sizes: from 50mm (2 “) to 1500mm (60”).
  • ATEX and FM approvals.
  • Materials: Aluminum body with stainless steel internals and Aluminum body with stainless steel (red color).

B-FLAP VALVE:

The B-FLAP is a mechanical device designed to prevent the spread of flame and pressure between different equipment / parts of the installation during the explosion.
The BFLAP is, together with other safety equipment, a part of the system that protects the equipment of the installation in an environment of danger of explosion.

ADVANTAGES:

  • Wide variety of sizes from DN 100 to DN800
  • Mechanical equipment that does not need power or activation system
  • Low pressure drop
  • High resistance to pressure
  • Position indicator (Optional)
  • Signs of dirt on the surface of the clapper (Optional)
  • Very simple installation, inspection and maintenance
  • Low maintenance costs
  • Mechanical closing when the clapper closes
  • Also suitable for equipment that operates with light metal dust.
  • Suitable equipment for explosion isolation in the pipeline: Filters, silos, mills, mixers…

FLAMELESS EXPLOSION VENTING DEVICE – FLEX:

Especially developed for technologies where extinguishing powder against is not accepted.

The FLEX equipment guarantees alleviating the explosion in internal or confined spaces without propagation of flame, pressure or heat around the installation point. Therefore, equipment and technologies that are located in areas of difficult access, can be protected by the flame arrester, without the usual increase in costs that require other types of equipment used to protect the facilities.

THE SYSTEM HAS 2 FUNCTIONS:

The relief of the explosion and the prevention of the prolongation of the explosion in free space are the two basic functions of the system.

The relief membranes open due to the rapid increase in pressure and the equipment absorbs the flame, solid particles from combustion and gases. In contrast to a classic explosion relief, the FLEX system is able to absorb this undesirable effect thanks to its construction.

The relief of the explosion can reach temperatures of up to 1500 ºC. During this process, the team will reduce the temperature, thanks to its design, to levels that are not dangerous for nearby equipment, operators and / or possible personnel movements.

ADVANTAGES:

  • Effective absorption of flame and heat
  • They allow a security area for equipment, structures and personnel movement
  • Effective dust absorption – so as not to contaminate the surroundings or technology
  • Stainless steel design available for food and pharmaceutical industry
  • High effectiveness and reliability of the system
  • Simple and maintenance-free installation
  • Elimination of the high costs of modifications in buildings
  • Advantageous solutions at an economical price

WATER SHOT:

Especially developed for technologies where fire extinguishing powder is not accepted. The WATER SHOT is a special HRD equipment equipped with a quick opening valve and other accessories with internal H2O instead of the usual extinguishing media.

Its main objective is to protect the technologies, which are cleaned with water in the normal process. Its application will undoubtedly be used in many other industries and in many different types of technology.

WHY USE WATER SHOT?

  • The technology material is not contaminated by fire extinguishing powder.
  • After the suppression of the explosion the technology should only be dried, it is not necessary to eliminate the agent like the normal powder ones.
  • The WATER SHOT is a highly ecological extinguishing agent, which pollutes the environment and quickly and economically refilled.
  • The WATER SHOT is a cost-effective and user-friendly device.

HRD SYSTEM – HIGH SPEED DOWNLOAD

The HRD system detects the start of the explosion inside a piece of equipment and then quickly suppresses the protected space. The reaction time of the equipment is counted in milliseconds. The HDR system effectively suppresses the explosion, limits the pressure of the explosion within the equipment under its resistance to pressure and prevents its destruction. Thanks to its perfect operation not only eliminate technological damage, but mainly protects human health.

IT IS COMPOSED OF:

CONTROL UNIT, of 1 or multiple zones evaluates and archives the information of the detector, activated extinction bottles, supervises the circuits for the connection of other sensors, provides data to superior systems and serves as an interface for the operators.

PRESSURE DETECTORS detect the start of the explosion by transmitting the information to the control unit extremely fast. Its advantage is a very short reaction time (in milliseconds) and variability of use.

SPECIAL HRD CONTAINERS equipped with very fast opening valves and other accessories contain the extinguishing agent under a stable pressure. When an explosion is detected, they provide an immediate and effective introduction of the extinguishing agent into the protected equipment. Variability of bottle sizes (5, 8, 20 or 50 liters), the rapid suppression of the explosion is its advantages. Easy handling and simple maintenance are a plus.

ESQUEMA DEL FUNCIONAMIENTO DE UN SISTEMA HRD EN UN FILTRO.

ADVANTAGES OF THE HRD SYSTEM:

  • Effective and proven technology
  • Rapid reaction of the system
  • High reliability
  • Use both in exterior and interior areas
  • Suitable solution for toxic products or other types of hazardous materials
  • Independent file of the detector data
  • Customization according to the customer’s quality requirements
  • Variety of use of components
  • Simple and quick replacement of components after activation
  • Easy handling and transport

THE HRD SYSTEM WILL PROTECT:

  • Filters and filtration units
  • Industrial vacuum cleaners
  • Silos
  • Mills
  • Dryers
  • Cyclones
  • Transporters
  • Deposits of dust
  • Elevators
  • Mixers
  • Shredders and other industrial equipment against the effects of the explosion.
  • Bucket elevators.

TAKE PREVENTIVE MEASURES AGAINST EXPLOSIONS. THE LAW REQUIRES IT.

In an environment that is constantly threatened by an explosion, the highly combustible suspended dust must be sufficiently safeguarded and protected against unwanted formation of an explosion. This obligation is imposed by a Directive of the European Parliament (Directive 94/9 / EC or ATEX100, Directive 2006/42 / EC and Directive 1999/92 / EC or ATEX137) and by the rules of legislation (mandatory) (EN 14373, EN 14460, EN 15089 and EN 1127-1). The HRD system is certified through a certification authority. The HRD system complies with all the requirements of the latest European standards (2006/42 / CE, Directive 94/9 / CE [ATEX 100], EN 14373).

SERVICES:

  • Distribution of equipment and accessories to prevent fires and explosions in industrial plants, thus protecting the health and life of workers, and reducing the risk of irreparable damage and possible losses in production.
  • Installation or change due to breakage or deterioration of the existing ones in equipment owned by the client.

ELEMENT OF PROTECTION IN EQUIPMENT WITH ATEX EXPLOSION RISK:

  • The commissioning of ATEX equipment must be carried out by qualified personnel
  • Fits Standard 94/9 / CE Atex
  • The control of the essential requirements of safety and health is guaranteed by the following regulations:
  • Certificate with directive EU34 / 2014.
  • Standard: UNE EN14797:2006, UNE EN 14491:2012, UNE EN 13463-1:2009, UNE EN 1127-1:2011, UNE EN 14994:2007, UNE EN 13980:2004, CE 0477 EUM1  11 Atex 0592 II GD

VENT PANELS:

Effective protection for deposits and technological equipment against ruptures and destruction during a possible explosion.

The storage and handling of industrial dusts are usually related to the potential danger of an explosion. These panels for explosive discharge are a perfect solution to reduce this risk and eliminate the losses that follow those explosions.

Vent panels offer a very effective and economical solution to protect against the damage caused by an explosion of solids.

Among its main advantages are:

  • High effectiveness and confidence
  • Long life of service
  • Resistivity against abrasion and impacts of mechanical particles and environmental conditions
  • Easy installation, change and easy availability of spare parts
  • Panels and auxiliary equipment of variable sizes
  • Economically advantageous solution

FLAME ARRESTERS:

A flame arrestor will eliminate a flame that will pass through it.

In the case of conductions with a certain length, the flame can acquire the character of a Detonation, therefore the Flame arrester must be designed to withstand the overpressure that this episode will entail.

  • Sizes: from 50mm (2 “) to 1500mm (60”).
  • ATEX and FM approvals.
  • Materials: Aluminum body with stainless steel internals and Aluminum body with stainless steel (red color).

B-FLAP VALVE:

The B-FLAP is a mechanical device designed to prevent the spread of flame and pressure between different equipment / parts of the installation during the explosion.
The BFLAP is, together with other safety equipment, a part of the system that protects the equipment of the installation in an environment of danger of explosion.

ADVANTAGES:

  • Wide variety of sizes from DN 100 to DN800
  • Mechanical equipment that does not need power or activation system
  • Low pressure drop
  • High resistance to pressure
  • Position indicator (Optional)
  • Signs of dirt on the surface of the clapper (Optional)
  • Very simple installation, inspection and maintenance
  • Low maintenance costs
  • Mechanical closing when the clapper closes
  • Also suitable for equipment that operates with light metal dust.
  • Suitable equipment for explosion isolation in the pipeline: Filters, silos, mills, mixers…

FLAMELESS EXPLOSION VENTING DEVICE – FLEX:

Especially developed for technologies where extinguishing powder against is not accepted.

The FLEX equipment guarantees alleviating the explosion in internal or confined spaces without propagation of flame, pressure or heat around the installation point. Therefore, equipment and technologies that are located in areas of difficult access, can be protected by the flame arrester, without the usual increase in costs that require other types of equipment used to protect the facilities.

THE SYSTEM HAS 2 FUNCTIONS:

The relief of the explosion and the prevention of the prolongation of the explosion in free space are the two basic functions of the system.

The relief membranes open due to the rapid increase in pressure and the equipment absorbs the flame, solid particles from combustion and gases. In contrast to a classic explosion relief, the FLEX system is able to absorb this undesirable effect thanks to its construction.

The relief of the explosion can reach temperatures of up to 1500 ºC. During this process, the team will reduce the temperature, thanks to its design, to levels that are not dangerous for nearby equipment, operators and / or possible personnel movements.

ADVANTAGES:

  • Effective absorption of flame and heat
  • They allow a security area for equipment, structures and personnel movement
  • Effective dust absorption – so as not to contaminate the surroundings or technology
  • Stainless steel design available for food and pharmaceutical industry
  • High effectiveness and reliability of the system
  • Simple and maintenance-free installation
  • Elimination of the high costs of modifications in buildings
  • Advantageous solutions at an economical price

WATER SHOT:

Especially developed for technologies where fire extinguishing powder is not accepted. The WATER SHOT is a special HRD equipment equipped with a quick opening valve and other accessories with internal H2O instead of the usual extinguishing media.

Its main objective is to protect the technologies, which are cleaned with water in the normal process. Its application will undoubtedly be used in many other industries and in many different types of technology.

WHY USE WATER SHOT?

  • The technology material is not contaminated by fire extinguishing powder.
  • After the suppression of the explosion the technology should only be dried, it is not necessary to eliminate the agent like the normal powder ones.
  • The WATER SHOT is a highly ecological extinguishing agent, which pollutes the environment and quickly and economically refilled.
  • The WATER SHOT is a cost-effective and user-friendly device.

HRD SYSTEM – HIGH SPEED DOWNLOAD

The HRD system detects the start of the explosion inside a piece of equipment and then quickly suppresses the protected space. The reaction time of the equipment is counted in milliseconds. The HDR system effectively suppresses the explosion, limits the pressure of the explosion within the equipment under its resistance to pressure and prevents its destruction. Thanks to its perfect operation not only eliminate technological damage, but mainly protects human health.

IT IS COMPOSED OF:

CONTROL UNIT, of 1 or multiple zones evaluates and archives the information of the detector, activated extinction bottles, supervises the circuits for the connection of other sensors, provides data to superior systems and serves as an interface for the operators.

PRESSURE DETECTORS detect the start of the explosion by transmitting the information to the control unit extremely fast. Its advantage is a very short reaction time (in milliseconds) and variability of use.

SPECIAL HRD CONTAINERS equipped with very fast opening valves and other accessories contain the extinguishing agent under a stable pressure. When an explosion is detected, they provide an immediate and effective introduction of the extinguishing agent into the protected equipment. Variability of bottle sizes (5, 8, 20 or 50 liters), the rapid suppression of the explosion is its advantages. Easy handling and simple maintenance are a plus.

ESQUEMA DEL FUNCIONAMIENTO DE UN SISTEMA HRD EN UN FILTRO.

ADVANTAGES OF THE HRD SYSTEM:

  • Effective and proven technology
  • Rapid reaction of the system
  • High reliability
  • Use both in exterior and interior areas
  • Suitable solution for toxic products or other types of hazardous materials
  • Independent file of the detector data
  • Customization according to the customer’s quality requirements
  • Variety of use of components
  • Simple and quick replacement of components after activation
  • Easy handling and transport

THE HRD SYSTEM WILL PROTECT:

  • Filters and filtration units
  • Industrial vacuum cleaners
  • Silos
  • Mills
  • Dryers
  • Cyclones
  • Transporters
  • Deposits of dust
  • Elevators
  • Mixers
  • Shredders and other industrial equipment against the effects of the explosion.
  • Bucket elevators.

TAKE PREVENTIVE MEASURES AGAINST EXPLOSIONS. THE LAW REQUIRES IT.

In an environment that is constantly threatened by an explosion, the highly combustible suspended dust must be sufficiently safeguarded and protected against unwanted formation of an explosion. This obligation is imposed by a Directive of the European Parliament (Directive 94/9 / EC or ATEX100, Directive 2006/42 / EC and Directive 1999/92 / EC or ATEX137) and by the rules of legislation (mandatory) (EN 14373, EN 14460, EN 15089 and EN 1127-1). The HRD system is certified through a certification authority. The HRD system complies with all the requirements of the latest European standards (2006/42 / CE, Directive 94/9 / CE [ATEX 100], EN 14373).

¿Do you need more info? ¡Contact us!

    Tu nombre y apellido:

    Tu e-mail

    Teléfono de contacto:

    ¿Qué productos te interesan?

    Entiendo y Acepto esta política de privacidad, marcando esta casilla.